Durable, silent and energy-saving
Call Center
Mobile
sales@flutech.co.th
@flutech
dot
ค้นหาสินค้า


  [Help]
dot
หมวดหมู่สินค้า
Coriolis Mass Flow Vortex Flow Meter
ROSS VALVES, Heavy Industrial Valve
Line Mounted Valve
Manual & Mechanical Valve
Air Preparation FRL
Safety Pneumatic Solution
Accessories
Flow Control,Quick Exhaust, Shuttle&Check Valve
Base Mounted Valve
ROSS Type...
Dust Collector System
Diaphragm Valve
Explosion Proof Product
Remote Solenoid Enclosure and Remote Pilot
Electronic Control Systems
Immersion Header Tank
Bulkhead Connector
Sensor Transmitter and Controller
Flow sensor
Level Sensor
Analysis Sensor
Temperature sensor
Controller
Pressure Sensor
BURKERT Sensor Type
Chemical Chart
Pneumatic อุปกรณ์ในระบบลม
"PNEUMAX" Air Cylinder & Accessories
AIRTEC Solenoid Valve 32,52,53
AIRTEC ISO Valve
AIRTEC NAMUR Valve
MP Filter,Regulator,Lubricator.,Dryer,ServOil,Injection Lubricator
"BURKERT" Singular Valve
Fitting, Tube, Accessories
Valves
Solenoid Valve Process and Control Valve
Valve-water and other neutral media
Angle Seat Valve
Ball Valve
Valve-Neutral gas media
Globe valve
Pneumatic Quarterturn Actuator
Valve-Steam up to 180 C
Valve-High Pressure up to 250 bar
Control Head
Electric Quarterturn Actuator
Valve-High Pressure up to 250 bar
Positioner & Process Controller
Diaphragm valve
Valve-Aggressive media
sales@flutech.co.th


ขอใบเสนอราคา


Durable, silent and energy-saving

 Durable, silent and energy-saving-Valves with Kick and Drop electronics

We include solutions with double coils and Kick and Drop electronics in its solenoid valve range. These devices stand out not only due to their silent operation, but also because they meet the strictest requirements as regards electromagnetic compatibility (EMC).

In the Kick and Drop (KD) electronics, the coil is initially overexcited by a high voltage pulse to generate the high starting power required to open the valve. After a few milliseconds, the electronics switch to an energy-saving holding power, thus drastically reducing power consumption. Thanks to the low power consumption, the max. self-heating of the valve is lower, which minimises the build-up of deposits and calcification and substantially extends the valve’s service life. Unlike the control units with pulse-width modulation (PWM) that are normally used, KD electronics do not emit noises that are disturbing to humans and animals.

 




บทความจากเรา

Automated process water & drinking water analysis on site
Bürkert @ ISPE 2019
Precise gas control for fermentation